Drip Irrigation Index
Rivulis T-Tape model list

Rivulis T-Tape 508-16-170

16-inch emitter spacing, 8-mil wall, and 0.17 GPM per 100 ft at 8 psi.

Check maximum run length

Reel specifications

Wall thickness
8 mil
Emitter spacing
16 in.
Filtration
120 mesh
Reel length
7,500 ft

Flow by pressure

PressureGPM per 100 ftZone estimate
8 psi0.17Use 8 psi in calculator

Maximum run length

Check the length of one line against the manufacturer’s chart.

Published limit

930 ft

Level ground · 90% uniformity

Rivulis T-Tape US data sheet. The table specifies level ground and 90% uniformity. It gives 8 psi as the flow rating and leaves the run-length test inlet pressure unspecified.

What to check for this reel

For a 600-ft block of tape, the listed rate gives about 1.02 GPM at 8 psi. Check the wetted pattern where crop spacing is closer than the 16-inch emitter interval.

Example zone demand

10 rows of 100 ft each would need about 1.70 GPM at the listed 8 psi. Check the flow available under pressure and the manufacturer’s run-length chart for your longest row and slope.

Search the full tape index or see a replacement comparison with fitting and filtration checks.

Sources